湖南电力 ›› 2026, Vol. 46 ›› Issue (5): 50-57.doi: 10.3969/j.issn.1008-0198.2026.05.007

• 电网运行与控制 • 上一篇    下一篇

考虑耐受不确定性的工业园区电压暂降区间评估方法

赵鹏, 何志强, 李彦平   

  1. 内蒙古电力(集团)有限责任公司呼和浩特供电分公司,内蒙古 呼和浩特 010050
  • 收稿日期:2026-05-28 修回日期:2026-07-23 发布日期:2026-11-06
  • 通信作者: 赵鹏(1984),男,高级技师,高级工程师,主要研究方向为电力系统继电保护及电能质量分析与治理。
  • 作者简介:何志强(1980),男,高级工程师,主要研究方向为电能质量分析与治理。李彦平(1989),男,高级工程师,主要研究方向为电能质量分析与治理。
  • 基金资助:
    内蒙古电力公司2024年科技项目(2024-3-2)

Interval Assessment Method for Voltage Sag in Industrial Parks Considering Tolerance Uncertainty

ZHAO Peng, HE Zhiqiang, LI Yanping   

  1. Inner Mongolia Power (Group) Co., Ltd. Hohhot Power Supply Branch, Hohhot 010050, China
  • Received:2026-05-28 Revised:2026-07-23 Published:2026-11-06

摘要: 针对工业园区内现有电压暂降区间评估方法忽略敏感设备耐受能力差异性与不确定性的问题,提出一种融合仿射算术与博弈论组合赋权的电压暂降严重程度评估方法,引入仿射算术处理设备耐受参数的不确定性,抑制传统区间运算的区间爆炸,从而更精确地量化暂降冲击。首先,在分析电压暂降传播机理的基础上,构建基于设备耐受特性的暂降耐受因子模型;其次,引入区间数表征设备耐受参数的不确定性,并采用仿射算术处理该不确定性,构建用户侧电压暂降综合严重程度的区间评估模型。以IEEE 30节点系统为实证对象,模拟不同故障场景下的电压暂降传播与设备响应。仿真结果表明,相较于传统区间算术,该方法所得评估区间的平均宽度缩减了80 %以上,显著降低了评估结果的保守性,能更精确地刻画设备耐受特性的不确定性,为工业园区电能质量治理与敏感设备选型提供科学依据。

关键词: 电压暂降, 程度评估, 敏感设备, 耐受特性, 仿射算术, 区间分析

Abstract: To address the issue that existing assessment methods fail to consider the differences and uncertainties in the tolerance capabilities of sensitive equipment within industrial parks, this paper proposes a novel interval assessment method for voltage sag severity by integrating affine arithmetic and game theory-combined weighting. The affine algorithm is introduced to handle the uncertainty of equipment tolerance parameters, aiming to overcome the “interval explosion” problem inherent in traditional interval operations, thereby quantifying the impact of voltage sags more precisely. First, the propagation mechanism of voltage sags is analyzed, and a sag tolerance factor model based on equipment tolerance characteristics is constructed. Second, interval number theory is introduced to characterize the uncertainty in equipment tolerance parameters. Affine arithmetic is employed to handle this uncertainty, mitigate the excessive conservatism of conventional interval operations, thereby ultimately establishing an interval assessment model for the comprehensive severity of voltage sags on the user side. Finally, the IEEE 30-bus system is used as a case study to simulate voltage sag propagation and equipment responses under different fault scenarios. Simulation results indicate that compared to traditional interval algorithms, the average width of the assessment intervals obtained by the proposed method is reduced by over 80%. This effectively suppresses the "interval explosion" phenomenon, significantly lowers the conservatism of the assessment results, and thus more accurately characterizes the uncertainty of equipment tolerance characteristics. This provides a reliable scientific basis for power quality management and sensitive equipment selection in industrial parks.

Key words: voltage sag, severity assessment, sensitive equipment, tolerance characteristics, affine arithmetic, interval assessment