湖南电力 ›› 2026, Vol. 46 ›› Issue (5): 135-141.doi: 10.3969/j.issn.1008-0198.2026.05.017

• 电力人工智能与数字化 • 上一篇    下一篇

结合小波变换与多尺度卷积时序融合网络的轴流泵声信号故障诊断

谢捷敏1,2,3,4, 黄波1,2,3,4, 唐传奇1,2,3, 张弘强1,2,3,4   

  1. 1.国网湖南省电力有限公司电力科学研究院,湖南 长沙 410208;
    2.高效清洁发电技术湖南省重点实验室,湖南 长沙 410208;
    3.国网湖南省电力公司智慧水电安全高效运行与控制实验室,湖南 长沙 410208;
    4.湖南省湘电试验研究院有限公司,湖南 长沙 410208
  • 收稿日期:2026-06-16 修回日期:2026-07-28 发布日期:2026-11-06
  • 通信作者: 谢捷敏(1989),工学博士,高级工程师,研究方向为水电机组状态监测与故障诊断。
  • 基金资助:
    国网湖南省电力有限公司科技项目(5216A525000T)

Fault Diagnosis of Axial-Flow Pump Acoustic Signals Based on DWT and Multi-Scale Convolutional Temporal Fusion Network

XIE Jiemin1,2,3,4, HUANG Bo1,2,3,4, TANG Chuanqi1,2,3, ZHANG Hongqiang1,2,3,4   

  1. 1. State Grid Hunan Electric Power Company Limited Research Institute, Changsha 410208, China;
    2. Hunan Province Key Laboratory of High Efficiency &Clean Power Technology, Changsha 410208, China;
    3. State Grid Hunan Electric Power Company Limited Smart Hydropower Safe and Efficient Operation and Control Laboratory, Changsha 410208, China;
    4. Hunan Xiangdian Test Research Institute Co., Ltd., Changsha 410208, China
  • Received:2026-06-16 Revised:2026-07-28 Published:2026-11-06

摘要: 传统模型在处理信噪比较低、非平稳的轴流泵声音信号时,存在单一感受野和时间跟踪能力差的局限性。针对以上问题,提出一种结合离散小波变换(discrete wavelet transform,DWT)与多尺度卷积时序融合网络(multi-scale convolutional temporal fusion network,MSFANet)的轴流泵声信号故障诊断方法(DWT-MSFANet)。首先,模型引入DWT对原始声信号进行预处理,有效滤除强环境背景噪声;其次,模型构建包含四个尺度卷积核的并行卷积分支,能够同步捕捉故障信号中高频微观瞬态机械冲击与低频宏观水力脉动特征;随后,模型将跨尺度空间特征输入门控循环单元(gated recurrent unit,GRU),进一步挖掘持续水力激振下故障演化的长程时序依赖关系;最后,模型通过自注意力机制对关键的故障时段进行加权聚焦。实例分析表明,该方法在各项对比指标上均比对比模型表现更佳。

关键词: 轴流泵, 多尺度卷积神经网络, 门控循环单元, 故障诊断

Abstract: When dealing with low signal-to-noise ratio and non-stationary axial flow pump sound signals, traditional models exhibit limitations in terms of single receptive fields and poor time tracking ability. To address these issues, this paper proposes a fault diagnosis method combining discrete wavelet transform and a multi-scale convolutional temporal fusion network (DWT-MSFANet). First, the model introduces the Discrete Wavelet Transform to preprocess the original acoustic signals, effectively filtering out intense environmental background noise. Second, a parallel convolutional architecture with four scales of convolutional kernels is constructed to simultaneously capture high-frequency, microscopic transient mechanical impacts and low-frequency, macroscopic hydraulic pulsation characteristics within the fault signals. Subsequently, the cross-scale spatial features are fed into a Gated Recurrent Unit to further excavate the long-range temporal dependencies of fault evolution under continuous hydraulic excitation. Finally, a self-attention mechanism is employed to execute a weighted focus on critical fault frequency bands. Case analysis demonstrates that the proposed method consistently outperforms baseline models across all evaluation metrics.

Key words: axial flow pump, multi-scale convolutional neural network, gated recurrent unit, fault diagnosis

中图分类号: